Hourly Confirmation Gate - NID Dispatch Review

Engineering & product review. Real data: 30-day aggregates + Day A (Jun 15 power event, 2,000 nodes) + Day B (Jun 23 quiet day, 1,597 nodes).

Active Event Correlation

Power event detected. Power-resolved tickets are 41% of OSP today (baseline 28%). NID scores inflated. 7-day rolling average will hold scores high for 5 to 7 days after power restoration.

Structural lag: 55 to 63% of NID critical flags point at nodes that hourly telemetry shows are currently healthy. See NID Lag Effect tab.

Power event in progress
Nodes flagged by NID
2,000
Would-dispatch without gate
2,000
No gate
Would-dispatch with gate
1,414
Bypass + dispatch
Suppressed / Held / Scheduled
586
Diverted
29.3% of dispatches diverted. 60.3% of nodes bypass on R-BYPASS-3 (chronic recurrence).

Verdict breakdown

Real verdicts computed from BigQuery pull. Click a segment to filter the table.

1,206
446
140
130
78

BYPASS is dominated by R-BYPASS-3 (3+ recurrences in 7d). 60 to 64% of NID-critical nodes are chronically recurring across both days.

60.3% of NID-critical nodes are chronically recurring.

On Day A, 60.3% of nodes (1,206 of 2,000) had been NID-critical 3 or more times in the previous 7 days. On Day B, the figure was 63.7%. These nodes bypass the gate (R-BYPASS-3) because chronic recurrence means standard suppression is not the right action. They need a different intervention strategy: convergence review, root cause investigation, or a structural fix.

The gate's primary value is on the remaining 36 to 40% (non-chronic). The chronic-recurrence population is a separate problem the gate surfaces but does not solve.

Filter:20 rows
NodeFacilityNIDDeg hrs todayLast-4hRecurrenceCustomers (peak/total)DispatchedOutcomeVerdictRule
21F106Bronx - Hub B (Dyre)0.00011/240/45 prior165/258Non/aBYPASSR-BYPASS-3
PB162PKBGWVHE0.15019/243/46 prior115/316Non/aBYPASSR-BYPASS-3
35E141Brooklyn - Hub M (St. Marks)0.16813/241/46 prior107/232Non/aBYPASSR-BYPASS-3
SM202PKBGWVHE0.24011/240/43 prior99/263Non/aBYPASSR-BYPASS-3
NG125NCGDTXHE0.00313/242/42 prior101/141YesexternalDISPATCHR-MAIN-1
NB083NWBRNCHE0.16317/243/41 prior96/317Non/aDISPATCHR-MAIN-2
BK45BBCKLWVHE0.18415/243/41 prior78/206Non/aDISPATCHR-MAIN-2
G424AGRTWTXHE0.28815/244/40 prior72/201Non/aDISPATCHR-MAIN-2
HNV217Hendersonville0.2381/241/41 prior90/392Non/aSCHEDULER-MAIN-3-adapted
G096AGNVLNCHE0.2031/240/42 prior58/229Non/aSCHEDULER-MAIN-3-adapted
NA006NRWSVAHUB0.2024/242/42 prior50/241Non/aSCHEDULER-MAIN-3-adapted
KN23AKSTNNCHE0.2591/240/41 prior44/153Non/aSCHEDULER-MAIN-3-adapted
JV024JCVLTXHE0.1345/241/40 prior92/133Non/aHOLDR-MAIN-DEFAULT
BK011BCKLWVHE0.15913/240/41 prior84/214Non/aHOLDR-MAIN-5
PR009KRMTWVHE0.18011/242/40 prior69/239Non/aHOLDR-MAIN-DEFAULT
PX163_PX168BCKLWVHE0.0468/240/42 prior66/202Non/aHOLDR-MAIN-5
MTHEBPKBGWVHE0.2279/240/40 prior87/227Non/aSUPPRESSR-MAIN-4
MT109PKBGWVHE0.1455/240/40 prior82/260Non/aSUPPRESSR-MAIN-4
HNV213Hendersonville0.0639/240/40 prior77/272Non/aSUPPRESSR-MAIN-4
TL203TYLRTXHE0.2411/240/40 prior54/151Non/aSUPPRESSR-MAIN-4

Data limitations: co_degradation_at_facility computed at hub level fires on 97 to 98% of rows and cannot drive R-BYPASS-2 in this version. NOC ticket join not yet wired, so R-BYPASS-1, R-BYPASS-4, R-BYPASS-5 and R-MAIN-6 cannot fire. recurrence_same_tod defaulted to false in the pull; R-MAIN-3 adapted to fire on any intermittent + prior recurrence.